mcpbeat

Matlab Vehicle Network Communication

matlab/matlab-vehicle-network-communication

Use when setting up vehicle network communication in MATLAB using Vehicle Network Toolbox. Covers CAN/CAN FD (fully implemented), with architecture for J1939, XCP, and future protocols. Handles hardware discovery, channel creation, bus configuration, message exchange, signal encoding/decoding, and analysis across all supported vendors. (Vector, Kvaser, PEAK-System, NI, SocketCAN, MathWorks Virtual).

26k tokens
context cost
the whole folder, loaded on every use
33
files
ships runnable scripts
0
copies elsewhere
how many repositories repackaged it
865
stars on the repo
on the repository, not the skill itself

Install

one command, takes just this skill from the repository
npx skills add https://github.com/matlab/matlab-agentic-toolkit --skill matlab-vehicle-network-communication

The instruction itself

26 sections, as written by the author

MATLAB Vehicle Network Communication

Prerequisites

  • MATLAB R2021a or later
  • Vehicle Network Toolbox installed (ver('vnt') to verify)
  • For physical hardware: vendor-specific drivers installed (Vector CANlib, Kvaser CANlib, NI-XNET, PEAK PCAN driver)
  • For testing without hardware: MathWorks Virtual channels are always available

Overview

Guide Claude through helping users establish vehicle network communication using MATLAB Vehicle Network Toolbox. This skill covers the full workflow from hardware discovery to message exchange across all supported protocols and vendors.

Implemented protocols:

  • CAN / CAN FD — fully documented

Planned protocols (architecture ready, not yet documented):

  • J1939 — parameter groups, transport protocol, address claiming
  • XCP — measurement, calibration, A2L file handling
  • Additional protocols as VNT adds support

When to Use

  • User wants to send/receive messages on a vehicle network bus in MATLAB
  • User is setting up a communication test bench or loopback verification
  • User asks about Vehicle Network Toolbox channel configuration
  • User encounters channel errors (initialization access, bus speed, no acknowledgment)
  • User wants to filter, decode, or analyze vehicle network messages
  • User asks which hardware works on their platform
  • User wants passive bus monitoring without affecting traffic
  • User needs to encode/decode signal data from messages

When NOT to Use

  • User wants to log/replay BLF files without live communication — use a BLF logging skill
  • User is building Simulink vehicle network blocks — use Simulink-specific skills
  • User needs CAN database file (DBC/LDF/A2L) creation or editing — this skill covers using existing files only
  • User is working with a protocol not yet documented in this skill (check protocol sections below)

Protocol Router

Use this decision tree to identify which protocol the user needs:

| User's Goal | Protocol | Reference Section |

|-------------|----------|-------------------|

| Send/receive CAN or CAN FD messages | CAN/CAN FD | references/can/ |

| Work with SAE J1939 parameter groups | J1939 | *Not yet documented* |

| ECU measurement or calibration via XCP/CCP | XCP | *Not yet documented* |

| General hardware discovery (any protocol) | Shared | references/shared/ |

If the user asks about a protocol not yet documented, inform them which protocols are currently covered and offer to help with those.

Shared Concepts (All Protocols)

Hardware Discovery

t = canChannelList;  % CAN/CAN FD/J1939 devices

All VNT protocols share the same hardware discovery mechanism. See references/shared/hardware-discovery.md.

Channel Lifecycle

All protocols follow the same lifecycle pattern:

Create Channel → Configure → Start → Operate → Stop/Cleanup

Key rules:

  • Configuration (bus speed, filters) must happen BEFORE start
  • clear ch releases the channel (equivalent to stop + destroy)
  • Use onCleanup(@() stop(ch)) for error-safe cleanup
  • Running channels hold InitializationAccess — blocking new channel creation

See references/shared/channel-lifecycle.md.

Vendor / Platform Matrix

| Vendor | Windows | Linux | Notes |

|--------|:-------:|:-----:|-------|

| Vector | Yes | No | Virtual channels if driver installed |

| NI | Yes | No | No channel index in constructor |

| Kvaser | Yes | Yes | Restart MATLAB after connecting hardware |

| PEAK-System | Yes | Yes | 10-arg clock-based configBusSpeed |

| SocketCAN | No | Yes | Configure speed at OS level via ip link |

| MathWorks Virtual | Yes | Yes | Always available, no driver needed |


CAN / CAN FD

Troubleshooting Gate

If the user reports a CAN/CAN FD problem — "not working", "trouble", "error", "can't connect", "no messages", hardware not detected, or any communication failure — you MUST do one of the following:

  • Domain-knowledge question ("why does X cause Y", "what's the maximum stub length for CAN FD", "explain bit rate switching") — answer from references/can/troubleshooting/l1-domain-knowledge.md without running diagnostics.
  • Actionable problem requiring diagnosisLoad references/can/troubleshooting/diagnostic-workflow.md BEFORE responding. Follow its Entry-Point Routing to select the correct starting step. Do NOT diagnose from this file. The tables, pitfalls, and patterns below are reference material for healthy operation — they are NOT a diagnostic procedure. Improvising from them produces wall-of-text responses with multiple guesses instead of structured one-question-at-a-time triage.

Core Workflow

digraph can_workflow {
    rankdir=TB;
    node [shape=box];

    discover [label="1. Discover Hardware\ncanChannelList"];
    decide [label="CAN Classic or CAN FD?" shape=diamond];
    create_classic [label="2a. Create Channel\ncanChannel(vendor, device, ch)"];
    create_fd [label="2b. Create FD Channel\ncanChannel(..., ProtocolMode='CAN FD')\nor canFDChannel(...)"];
    config [label="3. Configure Bus Speed\nconfigBusSpeed (vendor-specific syntax)"];
    start [label="4. Start Channel\nstart(ch)"];
    operate [label="5. Transmit / Receive\ntransmit, receive\ntransmitPeriodic, transmitEvent, replay"];
    cleanup [label="6. Cleanup\nstop(ch) or clear ch"];

    discover -> decide;
    decide -> create_classic [label="Classic"];
    decide -> create_fd [label="CAN FD"];
    create_classic -> config;
    create_fd -> config;
    config -> start;
    start -> operate;
    operate -> cleanup;
}

Post-Transmit Verification (MANDATORY)

After ANY transmit, verify the bus accepted the frame before reporting success:

pause(0.5);
fprintf('TEC=%d REC=%d BusStatus=%s\n', ch.TransmitErrorCount, ch.ReceiveErrorCount, ch.BusStatus);

| Result | Action |

|--------|--------|

| TEC=0, REC=0, ErrorActive | Healthy — report success |

| TEC>0 OR REC>0 OR not ErrorActive | Unhealthy — report counters to user, route to diagnostic workflow Step 0.5. Follow diagnostic Interaction Rules (one question at a time). |

Never claim "sent successfully" from transmit returning without error. It is non-blocking and returns immediately regardless of bus state. When routing to diagnostics, do NOT list multiple possible causes — let Step 0.5 identify the root cause and ask one targeted question.

CAN Classic vs CAN FD Decision

| Aspect | CAN Classic | CAN FD |

|--------|-------------|--------|

| Max payload | 8 bytes | 64 bytes |

| Message constructor | canMessage(id, ext, dlc) | canFDMessage(id, ext, dlc) or canMessage(..., ProtocolMode="CAN FD") |

| Channel creation | canChannel(vendor, device, ch) | Add 'ProtocolMode', 'CAN FD' or use canFDChannel |

| Bus speed config | Single speed | Arbitration + Data phase (vendor-specific syntax) |

| receive output | Objects or timetable | Always timetable |

| Valid DLCs | 0–8 | 0, 8, 12, 16, 20, 24, 32, 48, 64 |

Critical Patterns (Non-Obvious API Behavior)

These patterns are where the API behaves differently than expected. Follow these exactly.

attachDatabase operates on MESSAGES, not channels
% WRONG — will error
attachDatabase(ch, db);
ch.Database = db;  % only valid for name-based filterAllowOnly

% CORRECT — attach to received message object
rxMsg = receive(ch, 1);
attachDatabase(rxMsg, db);
speed = rxMsg.Signals.EngineSpeed;
transmitPeriodic + pack for live signal updates
% WRONG — manual loop blocks MATLAB, timing is inaccurate
while running
    pack(msg, newValue, 0, 16, 'LittleEndian');
    transmit(ch, msg);
    pause(0.1);
end

% CORRECT — hardware-timed, non-blocking
transmitPeriodic(ch, msg, 'On', 0.1);
start(ch);
pack(msg, newValue, 0, 16, 'LittleEndian');  % next cycle sends updated data
filterAllowOnly REQUIRES type argument for numeric IDs
% WRONG — errors with "Expected NAME to be one of these types: char, cell"
filterAllowOnly(ch, [0x180 0x181]);

% CORRECT — must specify 'Standard' or 'Extended'
filterAllowOnly(ch, [0x180 0x181], 'Standard');
filterAllowOnly(ch, [0x18FEF100], 'Extended');
CAN FD configBusSpeed is vendor-specific
% MathWorks Virtual / NI — simple 3-arg form works
configBusSpeed(ch, 500000, 2000000);

% Vector / Kvaser — REQUIRES 9-arg advanced timing form
configBusSpeed(ch, 500000, 2, 6, 3, 2000000, 2, 6, 3);

% PEAK-System — REQUIRES 10-arg clock-based form
configBusSpeed(ch, 20, 5, 1, 2, 1, 2, 1, 3, 1);
CAN FD receive ALWAYS returns timetable
% CAN FD channels ignore OutputFormat — always timetable
msgs = receive(fdCh, Inf);       % returns timetable
msgs.ID                          % numeric vector of IDs
msgs.Data{1}                     % uint8 vector for first message
% WRONG: msgs(1).Data, msgs.Data(1) — these error on timetable
transmitEvent fires on ANY .Data write (including pack)
transmitEvent(ch, msg, 'On');
start(ch);
pack(msg, value, 0, 16, 'LittleEndian');  % this auto-transmits!
% No explicit transmit() call needed — pack triggers it

Common Pitfalls

| Pitfall | Symptom | Fix |

|---------|---------|-----|

| Stale channel object | "lacks initialization access" | clear the variable or stop prior channel |

| canMessage for FD payload | "DATALENGTH must be <= 8" | Use canFDMessage or add ProtocolMode="CAN FD" |

| No acknowledging node | Transmit retries continuously | Ensure another node/channel is started on the bus |

| Claiming success without checking counters | User believes data sent; bus is ErrorPassive | ALWAYS check TEC/REC/BusStatus after transmit |

| Bus speed mismatch | Transmit succeeds, receive empty | All nodes must share same speed |

| configBusSpeed after start | Error | Must configure while channel is offline |

| Reusing variable | Error on creation | clear variable before creating new channel |

| configBusSpeed on SocketCAN | Not supported | Configure speed at OS level via ip link |

| CAN FD on PEAK-System Linux | Self-receive not supported | Use SocketCAN as workaround |

| unpack on timetable | "Incorrect number or types of inputs" | CAN FD always returns timetable; use typecast(data(1:2), 'int16') on raw bytes |

CAN References

Detailed API documentation (load on demand):

  • references/can/channel-creation.md — canChannel, canFDChannel, vendor-specific syntax
  • references/can/bus-speed-config.md — configBusSpeed, vendor-specific argument counts
  • references/can/message-creation.md — canMessage, canFDMessage, valid FD DLCs
  • references/can/transmit.md — transmit, transmitPeriodic, transmitEvent, replay
  • references/can/receive.md — receive, SilentMode, timetable output, FIFO behavior
  • references/can/filters.md — filterAllowOnly, filterBlockAll, filterAllowAll
  • references/can/database.md — canDatabase, attachDatabase, signal-level decode/encode
  • references/can/pack-unpack.md — pack, unpack, signal extraction, byte-order
  • references/can/message-extraction.md — extractAll, extractRecent, extractTime, discard

CAN Troubleshooting

See Troubleshooting Gate at the top of this section. Also route to diagnostics when the agent observes unhealthy bus state (TEC/REC > 0, BusStatus not ErrorActive) during any operation — including after transmit verification.

  • references/can/troubleshooting/diagnostic-workflow.md — Full diagnostic procedure (Phase 0 automation, L1 physical, L2 traffic analysis)
  • references/can/troubleshooting/script-interfaces.md — Function signatures, arguments, and outputs for all diagnostic/analysis scripts

Shared References

  • references/shared/hardware-discovery.md — canChannelList, platform constraints
  • references/shared/channel-lifecycle.md — start, stop, onCleanup, channel release
  • references/shared/limitations.md — Vendor/platform-specific constraints

----

Copyright 2026 The MathWorks, Inc.

----

How to use it

Copy the folder

Take matlab/matlab-vehicle-network-communication from the repository into ~/.claude/skills for personal use, or into .claude/skills inside a project.

Check the name does not clash

The agent identifies a skill by the name field in its header. Two skills with the same name cannot sit side by side — one of them will be ignored.