mcpbeat

Matlab Modernize Daq

matlab/matlab-modernize-daq

> Port MATLAB Data Acquisition Toolbox code from the discouraged (legacy) session-based interface (daq.createSession, addAnalogInputChannel, startBackground, DataAvailable listeners, queueOutputData, wait) to the recommended DataAcquisition interface (daq("ni"), addinput, start, ScansAvailableFcn, write, preload). Use when migrating legacy DAQ scripts, converting session-API calls, working with DataAcquisition objects, writing multi-feature DAQ scripts that combine triggers, callbacks, continuous acquisition, or analog output. Also use when a user says their DAQ script "used to work" or "errors on R20XX", since modernizing legacy session-API code is a frequent fix for those failures. ScansRequiredFcn, daq.createSession, addAnalogInputChannel, startBackground, queueOutputData, DataAvailable, evt.Data, evt.TimeStamps, wait(d), preload, discouraged, legacy, modernize, R2020a.

13k tokens
context cost
the whole folder, loaded on every use
6
files
ships runnable scripts
0
copies elsewhere
how many repositories repackaged it
865
stars on the repo
on the repository, not the skill itself

Install

one command, takes just this skill from the repository
npx skills add https://github.com/matlab/matlab-agentic-toolkit --skill matlab-modernize-daq

The instruction itself

14 sections, as written by the author

Port DAQ Code to the Modern DataAcquisition Interface

Translate legacy session-based Data Acquisition Toolbox code (daq.createSession, addAnalogInputChannel, DataAvailable listeners, startBackground, queueOutputData, wait) to the modern DataAcquisition interface introduced in R2020a (daq("ni"), addinput, ScansAvailableFcn, start, write, preload). Also covers writing new multi-feature DAQ scripts where the modern API patterns are easy to get wrong under cognitive load.

When to Use

  • Porting an existing script that calls daq.createSession, addAnalogInputChannel, addAnalogOutputChannel, addCounterInputChannel, addCounterOutputChannel, or addDigitalChannel.
  • Replacing DataAvailable / DataRequired / ErrorOccurred listeners with ScansAvailableFcn / ScansRequiredFcn / ErrorOccurredFcn.
  • Replacing startBackground / startForeground / s.wait() lifecycle calls.
  • Replacing queueOutputData with preload + write.
  • Writing a new DAQ script that combines two or more of: external triggers, continuous acquisition, callback-driven streaming, analog output with refill, or cross-callback state.
  • Debugging errors like Undefined function 'wait' for input arguments of type 'daq.interfaces.DataAcquisition' or Unrecognized method, property, or field 'Data' for class 'matlabshared.asyncio.buffer.ElementsAvailableInfo'.

When NOT to Use

  • Single-channel foreground acquisition with no trigger and no callbacks (e.g. "acquire 1 s of voltage from ai0 at 10 kHz and plot"). The modern API is straightforward at this scale and this skill would be unnecessary overhead.
  • Picking a DAQ vendor or evaluating non-NI hardware. This skill's evidence base is NI.
  • Signal processing or analysis of already-acquired data (filtering, spectral analysis, etc.). This skill only covers acquiring and generating data through the DataAcquisition interface, not post-processing it.
  • Simulink, App Designer, or real-time-target DAQ workflows.
  • Modernizing matlab.unittest test suites or framework-style test classes (parameterized fixtures, assumeTrue gating, arity-contract tests, helper-class hierarchies). The API substitutions in this skill apply, but the test-harness scaffolding (parent-class stripping, fixture redesign, retiring tests that target removed contracts) is out of scope. Use this skill to translate the API calls inside test bodies, then make the harness-level judgment calls separately.

Workflow

When porting a session-based script or composing a new multi-feature DAQ script, follow this order. Verify after every step — most failure modes in this domain are silent.

  • Inventory the legacy script (porting only). Identify: device(s), channel types, rate, continuous vs finite, trigger/clock connections, callbacks (DataAvailable/DataRequired/ErrorOccurred), state shared across callbacks, output queueing.
  • Translate vocabulary. Map every session-API token to its modern counterpart. Consult references/session-to-modern-mapping.md — load it whenever a session-API token appears in the legacy script. Common silent-rename traps: NotifyWhenDataAvailableExceedsScansAvailableFcnCount, NumberOfScans/NumScans → implicit (no equivalent argument), ExternalTriggerTimeoutDigitalTriggerTimeout, IsContinuous=truestart(d, "Continuous") argument.
  • Build the DataAcquisition object. d = daq("ni"), set d.Rate, add channels with addinput/addoutput. Apply per-channel properties via the channel handle returned by addinput/addoutput.
  • Wire triggers and clocks. Use references/canonical-snippets.md §1 — load it when the script involves addtrigger or addclock. Argument order is (d, type, role, trigSrc, trigDest) — Source is 4th, Destination is 5th. Verify: the returned trigger object's Source and Destination fields show what you intended.
  • Wire callbacks. Use canonical snippets §2 — load it when the script needs ScansAvailableFcn or ScansRequiredFcn. Inside the callback, always pull data via read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix") — the evt argument is matlabshared.asyncio.buffer.ElementsAvailableInfo and exposes only NumElementsAvailable, no Data, no TimeStamps. Strongly recommend wiring d.ErrorOccurredFcn = @(~,evt) fprintf("DAQ error: %s\n", evt.Error.message) — without it, exceptions inside other callbacks are silently swallowed and the run "succeeds" while every fire throws. For strict ports where the legacy script had no ErrorOccurred listener, surface this trade-off to the user instead of silently adding the handler — let them opt in.
  • Pick a state-sharing pattern (callbacks only). If a callback needs to maintain state across fires (running counters, phase accumulator, latch flags), see references/callback-state-patterns.md — load it any time a callback maintains state. Default: handle-class wrapper or nested function. Avoid src.UserData.X = src.UserData.X + ... field-mutation; it does not persist.
  • Wire the lifecycle. Use canonical snippets §3 — load it when blocking on completion. There is no wait(d) method on the modern object. For finite acquisitions, prefer start(d, "Duration", seconds(N)) then read or a Running poll. For continuous, set a stop condition inside the callback (if scansRead >= target; stop(src); end) and poll d.Running from the caller.
  • Run verifyDataAcquisition before live execution. Script: scripts/verifyDataAcquisition.m. Catches the four highest-frequency silent gaps (missing ErrorOccurredFcn, evt.Data in callback source, wait(d) token, UserData.X = UserData.X + ... field mutation) by inspecting the live object and grepping the source file. Run via mcp__matlab__run_matlab_file if available, or copy into the user's project.
  • Live verification. Run a short version (e.g. 1–2 s instead of the user's full duration). Check that the script reaches start cleanly, that the callback fires at least once, and that no errors print from ErrorOccurredFcn. Use mcp__matlab__run_matlab_file against a saved .m file, not mcp__matlab__evaluate_matlab_code — the eval-string buffer runs in script mode and rejects local/nested function definitions, which Pattern 5 and most callback bodies require.

Key Functions

| Function | Purpose | Toolbox | Available From |

|----------|---------|---------|----------------|

| daq | Create a DataAcquisition object (d = daq("ni")) | Data Acquisition Toolbox | R2020a |

| addinput | Add input channel (analog, counter, or digital) | Data Acquisition Toolbox | R2020a |

| addoutput | Add output channel | Data Acquisition Toolbox | R2020a |

| addtrigger | Add trigger connection: addtrigger(d, type, role, trigSrc, trigDest) | Data Acquisition Toolbox | R2020a |

| addclock | Add clock connection (similar signature) | Data Acquisition Toolbox | R2020a |

| read | Foreground acquire OR pull data inside ScansAvailableFcn | Data Acquisition Toolbox | R2020a |

| write | Write output samples (also from inside ScansRequiredFcn) | Data Acquisition Toolbox | R2020a |

| preload | Load initial output buffer before start(d, "Continuous"). Output channels only. | Data Acquisition Toolbox | R2020a |

| start | Begin background acquisition: start(d), start(d, "Continuous"), start(d, "Duration", seconds(N)) | Data Acquisition Toolbox | R2020a |

| stop | Stop a running acquisition | Data Acquisition Toolbox | R2020a |

| flush | Discard buffered scans before reading | Data Acquisition Toolbox | R2020a |

| daqlist | Enumerate available devices (replaces daq.getDevices) | Data Acquisition Toolbox | R2020a |

| daqreset | Reset DAQ subsystem (replaces daq.reset) | Data Acquisition Toolbox | R2020a |

Properties on DataAcquisition: Rate, Running, NumScansAcquired, NumScansOutputByHardware, ScansAvailableFcn, ScansAvailableFcnCount, ScansRequiredFcn, ScansRequiredFcnCount, ErrorOccurredFcn, DigitalTriggerTimeout, UserData.

Patterns

The five canonical patterns below appear in full, with verified code, in references/canonical-snippets.md. Inline below is the minimal recall snippet for each — enough to anchor the agent's memory under load. Load the reference for the full, runnable forms.

Pattern 1: Add an external start trigger

trg = addtrigger(d, "Digital", "StartTrigger", "External", "Dev1/PFI0");
trg.Condition = "RisingEdge";
d.DigitalTriggerTimeout = 30;

The 4th argument is the Source ("External" for an external signal). The 5th is the Destination (the device terminal). Reversing them is the most-frequent error in this domain. The trigger condition ("RisingEdge", "FallingEdge") is set on the trigger object returned by addtrigger (trg.Condition), not on the DataAcquisition object. There is no d.DigitalTriggerCondition property — inventing one passes static lint but errors at runtime.

Pattern 2: ScansAvailableFcn body — pull data via read, never evt.Data

d.ScansAvailableFcnCount = round(d.Rate * 0.5);
d.ScansAvailableFcn = @(src, ~) onBlock(src);
d.ErrorOccurredFcn  = @(~, evt) fprintf("DAQ error: %s\n", evt.Error.message);

function onBlock(src)
    [data, t] = read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix");
    plot(t, data); drawnow limitrate;
end

The evt argument carries only NumElementsAvailable; it has no Data or TimeStamps. Wiring ErrorOccurredFcn is strongly recommended — without it, callback exceptions are silently swallowed and the run "succeeds" while every fire throws. For strict ports of legacy scripts that did not have an ErrorOccurred listener, ask the user before adding one rather than inserting it silently.

Pattern 3: Block until acquisition completes — there is no wait(d)

start(d, "Duration", seconds(10));
while d.Running
    pause(0.05);
end

wait(d) does not exist on daq.interfaces.DataAcquisition. Poll d.Running, or rely on start(d, "Duration", ...) + a stop condition inside the callback.

Pattern 4: Continuous AO playback with auto-refill

d = daq("ni");
d.Rate = 1000;
addoutput(d, "Dev1", "ao0", "Voltage");
d.ScansRequiredFcnCount = d.Rate;
d.ScansRequiredFcn = @(src, ~) write(src, generateNextBlock());
preload(d, generateNextBlock());
preload(d, generateNextBlock());
start(d, "Continuous");

preload is output-only — calling it on input-only setups errors. Two preloaded blocks before start give the buffer headroom for the first ScansRequiredFcn to fire.

Pattern 5: Cross-callback state via nested function or handle class

function runStreamingAcquisition()
    d = daq("ni");
    addinput(d, "Dev1", "ai0", "Voltage");
    d.Rate = 1000;
    d.ScansAvailableFcnCount = 200;

    scansRead = 0;
    target    = d.Rate * 5;
    d.ScansAvailableFcn = @(src, ~) onBlock(src);
    d.ErrorOccurredFcn  = @(~, evt) fprintf("DAQ error: %s\n", evt.Error.message);

    start(d, "Continuous");
    while d.Running
        pause(0.05);
    end

    function onBlock(src)
        data = read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix");
        scansRead = scansRead + size(data, 1);
        if scansRead >= target
            stop(src);
        end
    end
end

Nested function captures scansRead by reference, so updates persist across fires. Do not use src.UserData.X = src.UserData.X + ... — that pattern does not persist; counters reset every fire and closed-loop control silently outputs zero forever. Full alternatives (handle class, full UserData rewrite) and their tradeoffs are in references/callback-state-patterns.md.

Conventions

  • Strongly recommend wiring d.ErrorOccurredFcn whenever any other *Fcn callback is set, since the listener swallows callback exceptions otherwise. For strict ports of legacy scripts that lacked an ErrorOccurred listener, surface the trade-off to the user rather than silently adding the handler — adding it is a defensible default but fidelity to the source is also defensible.
  • Always pull data via read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix") inside ScansAvailableFcn. Never reach for evt.Data or evt.TimeStamps.
  • Always verify the returned trigger object after addtrigger — confirm Source and Destination reflect intent.
  • Never use wait(d). Poll d.Running or use start(d, "Duration", ...).
  • Never mutate fields of d.UserData from inside a callback (src.UserData.X = src.UserData.X + ...). State must live in a closure-captured variable, a handle-class wrapper, or a whole-struct rewrite of UserData.
  • Never call preload on an input-only DataAcquisition. It is output-only.
  • Prefer start(d, "Duration", seconds(N)) over start(d, "NumScans", N) for finite acquisition. NumScans is silently coerced or ignored.
  • Prefer the modern function names: daqlist over daq.getDevices, daqreset over daq.reset, daq("ni") over daq.createSession('ni').

Common Mistakes

| Mistake | Why It's Wrong | Correct Approach |

|----------------------------------------------------------------|---------------------------------------------------------------------------------|---------------------------------------------------------------------------------|

| addtrigger(d, "Digital", "StartTrigger", "Dev1/PFI0", "External") | Source/Destination reversed. 4th arg is Source, 5th is Destination. | addtrigger(d, "Digital", "StartTrigger", "External", "Dev1/PFI0") |

| plot(evt.TimeStamps, evt.Data) inside ScansAvailableFcn | evt is ElementsAvailableInfo; only NumElementsAvailable. Throws silently. | [data, t] = read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix") |

| wait(d) | No such method on daq.interfaces.DataAcquisition. Throws. | while d.Running, pause(0.05); end |

| src.UserData.Counter = src.UserData.Counter + n | Field mutation through src.UserData does not persist across callback fires. | Closure variable in nested function, or handle-class wrapper. See callback-state-patterns.md. |

| preload(d, ...) on a DAQ with only input channels | preload is output-only. | For inputs, just call start(d, ...). No prepare/preload step needed. |

| start(d, "NumScans", 1000) | NumScans is ignored — emits warning. Buffer size determined by preload or read. | start(d, "Duration", seconds(N)), or rely on preload size. |

| s.IsContinuous = true; s.startBackground(); | Both are session-API. Modern API has no IsContinuous property. | start(d, "Continuous") |

| addlistener(d, 'DataAvailable', @cb) | Listener events were renamed to *Fcn properties on the object. | d.ScansAvailableFcn = @cb |

| s.queueOutputData(block) | Session-API. Modern API uses preload (initial) and write (refill). | preload(d, block) before start; write(d, block) from ScansRequiredFcn. |

References

  • references/session-to-modern-mapping.md — full rename table for every function and property that is commonly ported verbatim by mistake. Load whenever a session-API token appears in the legacy script.
  • references/canonical-snippets.md — minimal, self-contained, runnable forms of the five patterns above. Load when composing a multi-feature script and you want a verified anchor.
  • references/callback-state-patterns.md — four state-sharing options (UserData / closure / handle-class / nested function), when to pick which, and the silent failure modes of the wrong choice. Load when any callback needs cross-fire state.
  • scripts/verifyDataAcquisition.m — static-checks a DataAcquisition object and its source script before live execution. Returns a structured report flagging the four highest-frequency silent gaps.

----

Copyright 2026 The MathWorks, Inc.

----

How to use it

Copy the folder

Take matlab/matlab-modernize-daq from the repository into ~/.claude/skills for personal use, or into .claude/skills inside a project.

Check the name does not clash

The agent identifies a skill by the name field in its header. Two skills with the same name cannot sit side by side — one of them will be ignored.