matlab/create-sdi-run
> Import data into the Simulation Data Inspector (SDI) from MAT, CSV, or Excel files, from workspace variables, or from a Simulink simulation. Use when the user wants to view a logged file in SDI, load a bench-test log, or verify what a just-completed `Simulink.sdi.createRun` or `sim(model)` produced. Covers the `'file'`, `'vars'`, and `'namevalue'` sources of `createRun`, the auto-populate behavior after `sim()`, and post-import verification. Not for comparing existing runs (use `Simulink.sdi.compareRuns`); not for streaming data live during a running simulation (use `Simulink.sdi.createRunOrAddToStreamedRun` — a separate API); and not for authoring Gherkin or Simulink Test test cases, assertions, or regression tests (use `testing-simulink-models`). Do not activate on test-authoring or verification prompts even when no test-authoring skill is available — say so and stop.
npx skills add https://github.com/matlab/simulink-agentic-toolkit --skill create-sdi-run
Get data into the Simulation Data Inspector using the shortest path that works. Most agents reflexively read files into the workspace and rebuild signals by hand; this skill teaches the direct paths and when each applies.
.mat, .csv, or .xlsx file of logged data and wants to view it in SDI.sim(model) and wants to see the logged signals.timeseries, timetable, or Simulink.SimulationData.Dataset variables in the workspace and wants an SDI run.Simulink.sdi.createRun, Simulink.sdi.getAllRunIDs, or Simulink.sdi.getRun.Simulink.sdi.compareRuns).Simulink.sdi.createRunOrAddToStreamedRun), not a mode of createRun. Prompts like "stream data into SDI while my sim is running" belong to that API. Do not activate on those..mf4), ULG, ROS bag, CAN log, or HDF5 formats — see references/format-support.md for what SDI reads natively vs. what needs a different toolbox..feature files, Simulink Test cases, matlab.unittest classes, or any pass/fail assertions or regression tests for a model or subsystem — use testing-simulink-models (Gherkin-based model_test, requires Simulink Test). Prompts like "write a Gherkin test for X", "verify abs(-5) equals 5", "create a regression test for this subsystem", or any request whose deliverable is a test artifact belong there. Do not activate this skill on such prompts even when testing-simulink-models is unavailable — in that case, tell the user which skill is missing and stop.Answer these four questions in order. The first "yes" tells you what to do.
After sim(model) with signal logging enabled, SDI auto-populates one run. Do not call createRun — that produces a duplicate.
before = Simulink.sdi.getAllRunIDs;
simOut = sim("myModel");
after = Simulink.sdi.getAllRunIDs;
if numel(after) > numel(before)
Simulink.sdi.view; % done — just open the window
end
If no new run appeared, logging is off. Enable it via the Simulink Agentic Toolkit model_edit tool with a configure op setting DataLogging on the target port, then re-simulate — or fall back to Step 3 with simOut. As a last resort, ask the user to right-click a signal → Log Selected Signals in the Simulink editor themselves; that step is for the user to perform, not the agent.
Use the 'file' source. One call handles MAT, CSV, and Excel natively — no load, no readtable, no sheetnames loop.
runID = Simulink.sdi.createRun("bench_test","file","logs/bench_test.mat");
Excel with N sheets returns a 1×N int32 vector — one run ID per sheet. All returned runs inherit the base name; if the user needs sheet-named runs, rename each run in place with sheetnames() — do not delete and re-import per sheet:
runIDs = Simulink.sdi.createRun("cases","file","cases.xlsx"); % [id1, id2, ...]
sheets = sheetnames("cases.xlsx");
for k = 1:numel(runIDs)
Simulink.sdi.getRun(runIDs(k)).Name = sheets(k);
end
Time-column header rule (CSV and Excel). SDI's built-in reader requires the time column to be named literally time (case-insensitive). Headers like time_s, t, Time (s), Timestamp cause SDI:sdi:ImportError. Try 'file' first and catch the error — do not pre-inspect the header row and guess, because SDI's matching rules can differ from your interpretation. On SDI:sdi:ImportError, fall back to the readmatrix + array2timetable + 'vars' pattern (Step 3 / CSV pattern below). Do not rewrite the source file.
Other createRun failures. createRun can also throw for reasons this skill does not enumerate — corrupted files, unsupported data types inside a MAT/Excel, malformed structs, permission errors, unregistered custom readers. When you catch an error identifier that is not SDI:sdi:ImportError, do not invent a fix or silently retry. Surface the full error identifier and message to the user, list the file or variables involved, and suggest they inspect the source (e.g., whos("-file",path) for a MAT, or sheetnames(path) plus a per-sheet read for an Excel). Ask before attempting an alternative import path.
Two sources, different purposes:
'vars' — pass variables whose names or .Name properties are already correct. This is the default.'namevalue' — pass explicit signal names when the variables have no .Name metadata (e.g., bare arrays or unnamed timeseries).Timeseries whose .Name is already what you want:
% TEMPLATE — not executable
runID = Simulink.sdi.createRun("baseline","vars", speedTS, torqueTS);
Timetable — signals inherit the column names:
% TEMPLATE — not executable
runID = Simulink.sdi.createRun("baseline","vars", benchTT);
Bare arrays needing explicit names:
% TEMPLATE — not executable
runID = Simulink.sdi.createRun("baseline","namevalue", ...
{"velocity","load"}, {velocityData, loadData});
Gotcha (Gap E): if a timeseries passed to 'namevalue' has its own .Name set, .Name wins over the caller-supplied name. To force the name you want, either set ts.Name first and use 'vars', or clear it before 'namevalue'.
After every createRun or auto-populate:
ids = Simulink.sdi.getAllRunIDs;
run = Simulink.sdi.getRun(ids(end));
fprintf("Run %d: %s (%d signals)\n", ids(end), run.Name, run.SignalCount);
for k = 1:run.SignalCount
fprintf(" %s\n", run.getSignalByIndex(k).Name);
end
Simulink.sdi.view;
Verify against MATLAB via the MATLAB MCP server's evaluate_matlab_code tool. If SignalCount == 0, the import silently produced nothing — investigate the source, do not report success.
All available from R2023a with base Simulink; no additional toolbox required.
| Function | Purpose | Available From |
|---|---|---|
| Simulink.sdi.createRun(name) | Empty run — used with Run.add for a per-signal build; rarely the right first choice. | R2011b |
| Simulink.sdi.createRun(name,"file",path) | Import a .mat, .csv, or .xlsx file. Returns scalar int32 for MAT/CSV, 1×N int32 vector for N-sheet Excel. | R2011b |
| Simulink.sdi.createRun(name,"vars",v1,v2,...) | Import workspace variables whose names/.Name are correct. | R2011b |
| Simulink.sdi.createRun(name,"namevalue",names,values) | Import with explicit names. See Gap E caveat. | R2011b |
| Simulink.sdi.view | Open the SDI window. Safe to call repeatedly; opens only if not visible. | R2011b |
| Simulink.sdi.getAllRunIDs | Return int32 vector of every run's ID. Use before/after sim to detect auto-populate. | R2017a |
| Simulink.sdi.getRun(runID) | Return the Simulink.sdi.Run object for a run ID. | R2011b |
| Simulink.sdi.clear | Delete all SDI runs. Ask the user first — destructive. | R2011b |
Four createRun sources exist: empty, 'vars', 'namevalue', 'file'. When unsure, run help Simulink.sdi.createRun.
runID = Simulink.sdi.createRun("sensor_log","file","data/sensor_log.mat");
Simulink.sdi.view;
The variables inside the MAT file may be timeseries, timetable, Simulink.SimulationData.Dataset, or legacy struct-with-time — SDI's reader picks them up automatically.
'file', catch, fall back)Attempt the one-liner first. On SDI:sdi:ImportError, fall back to the timetable path — do not rewrite the file:
try
runID = Simulink.sdi.createRun("bench_run","file","logs/bench_run.csv");
catch ME
if strcmp(ME.identifier,"SDI:sdi:ImportError")
raw = readmatrix("logs/bench_run.csv");
headers = string(readcell("logs/bench_run.csv","Range","1:1"));
tt = array2timetable(raw(:,2:end), ...
"RowTimes", seconds(raw(:,1)), ...
"VariableNames", headers(2:end));
runID = Simulink.sdi.createRun("bench_run","vars", tt);
else
rethrow(ME);
end
end
Assumes the time column is column 1 and expressed in seconds — the common case for bench logs. If the time column sits elsewhere or uses different units, adjust the index or wrap it with the appropriate duration constructor (milliseconds, minutes, …) before passing to RowTimes.
One createRun call per file. Every returned run initially inherits the base name you supplied — SDI does not auto-apply sheet names. Rename in place with sheetnames(); do not delete and re-import per sheet. The same time-column-header rule applies as for CSV — if a sheet's time column is not named time, createRun throws SDI:sdi:ImportError; wrap this call in the same try-then-fallback shown in the CSV pattern, using readmatrix(...,"Sheet",sheets(k)) and readcell(...,"Sheet",sheets(k),"Range","1:1") per sheet.
runIDs = Simulink.sdi.createRun("test_matrix","file","data/two_runs.xlsx");
% runIDs is a 1xN int32 vector — one ID per sheet, all named "test_matrix".
sheets = sheetnames("data/two_runs.xlsx");
for k = 1:numel(runIDs)
run = Simulink.sdi.getRun(runIDs(k));
run.Name = sheets(k); % rename in place to the sheet name
fprintf("Sheet run: %s (%d signals)\n", run.Name, run.SignalCount);
end
To restrict to specific sheets, use the sheets name-value — the returned vector is trimmed accordingly:
runIDs = Simulink.sdi.createRun("cases","file","cases.xlsx", ...
sheets=["baseline","variant"]);
before = Simulink.sdi.getAllRunIDs;
simOut = sim("controller_test");
after = Simulink.sdi.getAllRunIDs;
if numel(after) > numel(before)
Simulink.sdi.view; % logged signals already imported
else
% No auto-populate — logging is off. Enable it and re-simulate, or
% pass simOut through createRun as a fallback:
Simulink.sdi.createRun("run_from_simout","vars", simOut);
Simulink.sdi.view;
end
Set .Name before 'vars'. This avoids the 'namevalue' override trap.
data = load("data/speed_torque.mat");
speed = data.speed;
torque = data.torque;
speed.Name = "velocity";
torque.Name = "torqueNm";
runID = Simulink.sdi.createRun("baseline","vars", speed, torque);
Always
createRun. Use Simulink.sdi.getAllRunIDs before and after sim(model). If a new run appeared, sim already imported the logged signals — call Simulink.sdi.view and stop.'file' source for .mat, .csv, .xlsx. It handles the read and the signal-naming for you. Reserve load/readtable/sheetnames for the CSV time-column fallback and for genuinely workspace-first workflows.SignalCount. After every import, confirm at least one signal exists. Zero signals means the import failed silently.help Simulink.sdi.createRun if you are unsure which source applies. The four sources are the entire API surface for import.Ask First
Simulink.sdi.clear — deletes every run. Confirm with the user before running.time) — prefer the timetable fallback pattern instead of altering user data.SDI:sdi:ImportError failure — surface the error to the user first, then ask which path they want.Never
Simulink.sdi.createRunFromFile does not exist. Use Simulink.sdi.createRun(name,"file",path).load / readtable / manual timeseries construction / Run.add when the 'file' source handles the same file natively.namevalue names take precedence over timeseries.Name — .Name wins. See Gap E in Common Mistakes.SignalCount and the signal names.| Mistake | Why It's Wrong | Correct Approach |
|---|---|---|
| Reading MAT/CSV/Excel yourself and calling createRun(...,"vars",...) | Duplicates the 'file' source's work; loses SDI's automatic signal-name handling; scales badly for multi-sheet Excel. | Simulink.sdi.createRun(name,"file",path). |
| Deleting the multi-sheet import and re-calling createRun in a per-sheet loop because both runs share the base name | Discards the correct one-call 'file' import and violates the "single call handles sheet expansion" convention. All runs from one Excel file inherit the base name — they are not auto-renamed to sheet names. | Keep the one createRun(...,"file",xlsx) call and rename each run in place: Simulink.sdi.getRun(runIDs(k)).Name = sheets(k). |
| Calling createRun(...,"namevalue",{"SimOut"},{simOut}) after sim(model) | With signal logging on, sim already imported the run. This adds a duplicate. | sim(model); Simulink.sdi.view; (verify with getAllRunIDs before/after). |
| Using Simulink.sdi.createRunFromFile | Function does not exist. Hallucination. | Simulink.sdi.createRun(name,"file",path). |
| Passing namevalue names when the timeseries has its own .Name | .Name overrides the caller-supplied name silently — Gap E. | Set ts.Name first, then use 'vars'. Or clear .Name before 'namevalue'. |
| Pre-inspecting the header and skipping 'file' because you *think* the time column is misnamed | Your guess can differ from SDI's actual matching rules; skipping 'file' costs the automatic signal handling. | Try 'file' first, catch SDI:sdi:ImportError, then use the timetable fallback (Step 3 / CSV pattern). |
.mat, .csv, or .xlsx.createRun sources side-by-side with return-value shapes and name-value options. Consult when picking a source or debugging return values.----
Copyright 2026 The MathWorks, Inc.
----
Take matlab/create-sdi-run from the repository into ~/.claude/skills for personal
use, or into .claude/skills inside a project.
The agent identifies a skill by the name field in its header. Two skills with the
same name cannot sit side by side — one of them will be ignored.