mcpbeat Sign in

The Cable Code MCP Server

answering

The Cable Code is answering right now. Last checked 4 min ago. It exposes 8 tools.

Decode cables in 66 coding systems; design, rate and check them; find equivalents; size drums.

Uptime history 9 days of history · worst day 99%
9 days agonow
100.0%
Uptime 24h
91 of 91 checks
8
Tools
read from the server
408 ms
Response time
average over 24h
open, no key
Access
streamable-http

What changed 17

Every tool that appeared, vanished or quietly changed what it asks for. Recorded since 18 October 2026. No other catalogue keeps this.

26 Oct a tool appeared extract_datasheet
25 Oct a tool appeared write_specification
23 Oct 3 tools changed the parameters they ask for4 times that day design_cable, drum_fit, find_equivalents
23 Oct 2 tool descriptions were rewritten design_cable, drum_fit
23 Oct a tool appeared design_presets
22 Oct a tool appeared drum_fit
20 Oct a tool changed the parameters it asks for find_equivalents
18 Oct 2 tools appeared check_cable, find_equivalents
18 Oct 2 tool descriptions were rewritten check_cable, design_cable
18 Oct 2 tools changed the parameters they ask for check_cable, design_cable
and 1 more, back to 18 October 2026

The Cable Code missed one check this week

Everything else answered, so this is steady rather than shaky. We check every 15 minutes, which is how a one-off gets told apart from the start of a pattern, and how you hear about the next one within the hour instead of from your users.

Three servers free · no card

Connect this server

Endpoint below is the one we actually reach during checks — not the one copied from a README. Last verified 4 min ago.

run in your terminal
claude mcp add thecablecode --transport http https://thecablecode.com/mcp
Settings → Connectors → Add custom connector, then paste this address
https://thecablecode.com/mcp
~/.codex/config.toml
[mcp_servers.thecablecode]
url = "https://thecablecode.com/mcp"
.cursor/mcp.json
{
  "mcpServers": {
    "thecablecode": {
      "url": "https://thecablecode.com/mcp"
    }
  }
}
.vscode/mcp.json
{
  "servers": {
    "thecablecode": {
      "type": "http",
      "url": "https://thecablecode.com/mcp"
    }
  }
}

Available tools 8

Read directly from the server with tools/list, grouped by what they act on. If a tool disappears, we record the date.

design
design_cable
Design and size a cable (power, control, LAN, coaxial, fibre) from a sentence (Turkish or English, e.g. "3-core collective screen 12/20 kV 3x95/25 Al, longitudinally watertight") or a spec: every layer's thickness with its source (IEC 60502, HD 603 / 620, BS, EN 50525, NEC / UL and more; IEC 60228), the overall diameter, the designation and the decoder's reading of it, and the estimated weight, bending radius, pulling force, IEC 60757 colour codes and MV field stress with their sources; a bare designation works as the sentence; optional XML, DXF, SVG, CSV, GLB, STEP (3D CAD) and a PDF datasheet. Deterministic, no LLM; a nominal calculation, not a datasheet.
design_presets
The cable designer's presets (power, MV, HV, North American, building wire, cords, control, LAN, coaxial, fibre), each with the sentence that builds it in design_cable and its designation, and the standards a design_cable spec may name with their voltages, core counts and sections. Free, outside the daily free calls.
cable
check_cable
Check a power cable against a standard's nominal rules: a designation with size and voltage, a designer design, or the construction a maker's datasheet or tender offer states (layers with nominal and minimum thicknesses, screen and armour data). Rule sets: IEC 60502-1 / -2, IEC 60228, HD 603 3-G / 5-G, HD 620 10-J / M / D / C / K, BS 5467, BS 6724, BS 7846, BS 6622, or "auto" for the standards the cable claims. Every rule with required, found, pass / fail / not checkable and its source (standard, edition, clause or table, page, how firmly seen). Deterministic, no LLM. A check against nominal rules, not a certificate or a type test.
decode
decode_cable_code
Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 59 more of its 66 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM.
drum
drum_fit
Which cable drum (reel) a length of cable needs, or how much one drum takes: whole layers and whole turns on a wound diameter of 1.05 x OD with a freeboard under the flange rim, an estimate within a few per cent of cable makers' own capacity tables (most online tools overstate by 20 to 40 %). Drums are KTG, Nordic K, older DIN, Spanish, NEMA, Turkish, Brazilian and Chinese series and makers' own sizes (plastic and plywood reels among them) as their makers print them, each with its source; the barrel check uses the KTG minimum barrel table, and the cable's datasheet wins; a load rating is the maker's own. Free, deterministic, no LLM.
equivalents
find_equivalents
Find the equivalents of a power cable in other countries' standards ("the Dutch equivalent of this Swedish cable"): the decoded cable is rebuilt under each target rule set (IEC 60502, HD 603, HD 620 sections J/M/D/C/K, BS 5467/6724/7846/6622, EN 50618, HD 627) with the same conductor, section, cores, voltage, screen, armour and sheath, then compared layer by layer with the source of every value. Verdict per standard: equivalent, close (with the differences) or none (with the reason), and the name in that country's letters where sourced. Deterministic, no LLM. Never a statement of interchangeability: the buyer's specification decides.
extract
extract_datasheet
Read a power cable datasheet (a maker PDF, an https link to one, or pasted datasheet or tender text) into constructions: every cable size it states with voltage, cores, conductor, each layer with its nominal and smallest thickness, screen and armour data, diameters and the claimed standards, each with the page and the row it was read from, the values that could not be read and the ones the reader is unsure of. The reading is done by an LLM (Claude) and shown as read; it decides nothing. Each construction is ready for check_cable / POST /api/v1/check, and with standard set every row is checked by the deterministic rule engine in the same call, each rule with its clause and source. Review the values before relying on a verdict.
specification
write_specification
Write the cable specification for a tender: one cable, or a project of up to 30 cables, each as design_cable takes it (a sentence, a bare designation, a spec or a design), plus the project's requirements (rodent, termite, UV, cold, oil, watertightness, fire, armour and more, each with the construction chosen to meet it). Returns, per cable, the specification in tender order (scope, standards, construction with each layer's thickness and source, additional requirements with their test methods, tests, marking, drums, documents, deviations) as Markdown and plain text, and the required / offered schedule (GTP) as CSV and as JSON rows: REQUIRED filled from the design with each value's source, OFFERED left for the bidder. The same text a Pro member downloads from the designer, written by the same code. Deterministic, no LLM; a draft to check against the editions in force.

Endpoints

URLTransportStateLatencyChecked
https://thecablecode.com/mcp streamable-http answering 244 ms 4 min ago

Alternatives to The Cable Code

same job, measured the same way
Brandpilot MCP
by brandpilot

BrandPilot brands and design systems for coding agents: tokens, design context, repo rules.

197 installs/wk answering
Design System
by zaklad

Build and manage your design system with AI: tokens, themes, components, icons, Figma and code.

answering
Prumo
by tomd4vs

Checks the context files a coding agent reads against the git index, and reports what drifted.

42 installs/wk local only
AI Act Article 50 Audit
by jmshinhwa

Finds the AI call sites, generation code and system prompts that trigger EU AI Act Article 50 disclo

33 installs/wk local only
21st.dev
by 21st

Find UI components and themes, retrieve code, and generate with hosted 21st AI when enabled.

answering
AIStrategyMiner
by aistrategyminer

Design trading strategies with your AI and open them in a visual no-code Strategy Builder.

7 tools answering
seatledger
by agentwares

Local ledger of Claude Code and Codex tokens, API-equivalent cost, limits and token-rate changes.

31 installs/wk local only
Rams
by rams

Design review for UI code and live pages: quick checks, 0-100 scored reviews, fixes as patches

5 tools answering

The Cable Code — questions

Answers built from our own checks of this server.

What can The Cable Code do?
It exposes 8 tools, read directly from the server on our last check. Among them: check_cable, decode_cable_code, design_cable, design_presets, drum_fit, extract_datasheet and 2 more. The full list with descriptions is on this page — we take it from the server itself via tools/list, not from a README. How MCP servers expose tools in the first place →
Is The Cable Code working right now?
We send a real MCP handshake every 15 minutes. Over the last 24 hours 91 of 91 checks got a reply (100.0%), average response time 408 ms. The bar chart above shows every period we have measured.
How do I connect The Cable Code?
Copy the ready config from this page. We generate it for Claude Code, Claude Desktop, Codex, Cursor and VS Code, each in the form that client actually reads. It is a remote server, so there is nothing to install — the client connects to the address.
Does The Cable Code need an API key?
No. The Cable Code completed a full MCP handshake with us as an anonymous client and listed its tools without asking for anything. All 8 of them are readable on this page. This is what we observed, not what the docs claim.
How fast is The Cable Code?
It answers our handshake in 408 ms on average, which is faster than 34% of all working MCP servers we measure. The comparison comes from our own checks across the whole registry, every 15 minutes.