mcpbeat

Aoti Debug

pytorch/aoti-debug

Debug AOTInductor (AOTI) errors and crashes. Use when encountering AOTI segfaults, device mismatch errors, constant loading failures, or runtime errors from aot_compile, aot_load, aoti_compile_and_package, or aoti_load_package.

3k tokens
context cost
the whole folder, loaded on every use
2
files
instructions only
0
copies elsewhere
how many repositories repackaged it
102168
stars on the repo
on the repository, not the skill itself

Install

one command, takes just this skill from the repository
npx skills add https://github.com/pytorch/pytorch --skill aoti-debug

What comes with it

6 661 bytes besides the instruction
triton-index-out-of-bounds.md

The instruction itself

20 sections, as written by the author

AOTI Debugging Guide

This skill helps diagnose and fix common AOTInductor issues.

Error Pattern Routing

Check the error message and route to the appropriate sub-guide:

Triton Index Out of Bounds

If the error matches this pattern:

Assertion `index out of bounds: 0 <= tmpN < ksM` failed

→ Follow the guide in triton-index-out-of-bounds.md

All Other Errors

Continue with the sections below.


First Step: Always Check Device and Shape Matching

For ANY AOTI error (segfault, exception, crash, wrong output), ALWAYS check these first:

  • Compile device == Load device: The model must be loaded on the same device type it was compiled on
  • Input devices match: Runtime inputs must be on the same device as the compiled model
  • Input shapes match: Runtime input shapes must match the shapes used during compilation (or satisfy dynamic shape constraints)
# During compilation - note the device and shapes
model = MyModel().eval()           # What device? CPU or .cuda()?
inp = torch.randn(2, 10)           # What device? What shape?
compiled_so = torch._inductor.aot_compile(model, (inp,))

# During loading - device type MUST match compilation
loaded = torch._export.aot_load(compiled_so, "???")  # Must match model/input device above

# During inference - device and shapes MUST match
out = loaded(inp.to("???"))  # Must match compile device, shape must match

If any of these don't match, you will get errors ranging from segfaults to exceptions to wrong outputs.

Key Constraint: Device Type Matching

AOTI requires compile and load to use the same device type.

  • If you compile on CUDA, you must load on CUDA (device index can differ)
  • If you compile on CPU, you must load on CPU
  • Cross-device loading (e.g., compile on GPU, load on CPU) is NOT supported

Common Error Patterns

1. Device Mismatch Segfault

Symptom: Segfault, exception, or crash during aot_load() or model execution.

Example error messages:

  • The specified pointer resides on host memory and is not registered with any CUDA device
  • Crash during constant loading in AOTInductorModelBase
  • Expected out tensor to have device cuda:0, but got cpu instead

Cause: Compile and load device types don't match (see "First Step" above).

Solution: Ensure compile and load use the same device type. If compiled on CPU, load on CPU. If compiled on CUDA, load on CUDA.

2. Input Device Mismatch at Runtime

Symptom: RuntimeError during model execution.

Cause: Input device doesn't match compile device (see "First Step" above).

Better Debugging: Run with AOTI_RUNTIME_CHECK_INPUTS=1 for clearer errors. This flag validates all input properties including device type, dtype, sizes, and strides:

AOTI_RUNTIME_CHECK_INPUTS=1 python your_script.py

This produces actionable error messages like:

Error: input_handles[0]: unmatched device type, expected: 0(cpu), but got: 1(cuda)

Debugging CUDA Illegal Memory Access (IMA) Errors

If you encounter CUDA illegal memory access errors, follow this systematic approach:

Step 1: Sanity Checks

Before diving deep, try these debugging flags:

AOTI_RUNTIME_CHECK_INPUTS=1
TORCHINDUCTOR_NAN_ASSERTS=1

These flags take effect at compilation time (at codegen time):

  • AOTI_RUNTIME_CHECK_INPUTS=1 checks if inputs satisfy the same guards used during compilation
  • TORCHINDUCTOR_NAN_ASSERTS=1 adds codegen before and after each kernel to check for NaN

Step 2: Pinpoint the CUDA IMA

CUDA IMA errors can be non-deterministic. Use these flags to trigger the error deterministically:

PYTORCH_NO_CUDA_MEMORY_CACHING=1
CUDA_LAUNCH_BLOCKING=1

These flags take effect at runtime:

  • PYTORCH_NO_CUDA_MEMORY_CACHING=1 disables PyTorch's Caching Allocator, which allocates bigger buffers than needed immediately. This is usually why CUDA IMA errors are non-deterministic.
  • CUDA_LAUNCH_BLOCKING=1 forces kernels to launch one at a time. Without this, you get "CUDA kernel errors might be asynchronously reported" warnings since kernels launch asynchronously.

Step 3: Identify Problematic Kernels with Intermediate Value Debugger

Use the AOTI Intermediate Value Debugger to pinpoint the problematic kernel:

AOT_INDUCTOR_DEBUG_INTERMEDIATE_VALUE_PRINTER=3

This prints kernels one by one at runtime. Together with previous flags, this shows which kernel was launched right before the error.

To inspect inputs to a specific kernel:

AOT_INDUCTOR_FILTERED_KERNELS_TO_PRINT="triton_poi_fused_add_ge_logical_and_logical_or_lt_231,_add_position_embeddings_kernel_5" AOT_INDUCTOR_DEBUG_INTERMEDIATE_VALUE_PRINTER=2

If inputs to the kernel are unexpected, inspect the kernel that produces the bad input.

Additional Debugging Tools

Logging and Tracing

  • tlparse / TORCH_TRACE: Provides complete output codes and records guards used
  • TORCH_LOGS: Use TORCH_LOGS="+inductor,output_code" to see more PT2 internal logs
  • TORCH_SHOW_CPP_STACKTRACES: Set to 1 to see more stack traces

Common Sources of Issues

  • Dynamic shapes: Historically a source of many IMAs. Pay special attention when debugging dynamic shape scenarios.
  • Custom ops: Especially when implemented in C++ with dynamic shapes. The meta function may need to be Symint'ified.

API Notes

Deprecated API

torch._export.aot_compile()  # Deprecated
torch._export.aot_load()     # Deprecated

Current API

torch._inductor.aoti_compile_and_package()
torch._inductor.aoti_load_package()

The new API stores device metadata in the package, so aoti_load_package() automatically uses the correct device type. You can only change the device *index* (e.g., cuda:0 vs cuda:1), not the device *type*.

Environment Variables Summary

| Variable | When | Purpose |

|----------|------|---------|

| AOTI_RUNTIME_CHECK_INPUTS=1 | Compile time | Validate inputs match compilation guards |

| TORCHINDUCTOR_NAN_ASSERTS=1 | Compile time | Check for NaN before/after kernels |

| PYTORCH_NO_CUDA_MEMORY_CACHING=1 | Runtime | Make IMA errors deterministic |

| CUDA_LAUNCH_BLOCKING=1 | Runtime | Force synchronous kernel launches |

| AOT_INDUCTOR_DEBUG_INTERMEDIATE_VALUE_PRINTER=3 | Compile time | Print kernels at runtime |

| TORCH_LOGS="+inductor,output_code" | Runtime | See PT2 internal logs |

| TORCH_SHOW_CPP_STACKTRACES=1 | Runtime | Show C++ stack traces |

How to use it

Copy the folder

Take pytorch/aoti-debug from the repository into ~/.claude/skills for personal use, or into .claude/skills inside a project.

Check the name does not clash

The agent identifies a skill by the name field in its header. Two skills with the same name cannot sit side by side — one of them will be ignored.