Applies layered n-tier architecture with enforced boundaries. Use when designing moderate systems needing clear presentation, domain, and persistence layers.
2k tokens
context cost
the whole folder, loaded on every use
1
files
instructions only
0
copies elsewhere
how many repositories repackaged it
324
stars on the repo
on the repository, not the skill itself
Install
one command, takes just this skill from the repository
When teams need clear architectural boundaries and a familiar structure for moderate-sized systems.
When compliance or operations teams require clear separation of concerns (e.g., UI vs. domain logic vs. persistence).
When the deployment artifact remains a monolith, but code clarity and separation are degrading.
When NOT To Use This Paradigm
When high scalability demands require independent scaling of components
When multiple teams need independent deployment cycles
When complex business logic requires frequent cross-layer communication
When microservices architecture is already planned or in place
When real-time processing requirements make layered communication too slow
Adoption Steps
Define the Layers: Establish a clear set of layers. A common stack includes: Presentation -> Application/Service -> Domain -> Data Access.
Enforce Dependency Direction: Code in a given layer may only depend on the layer immediately below it. Forbid any "upward" dependencies or imports.
Centralize Cross-Cutting Concerns: Implement concerns like logging, authentication, and validation as centralized middleware or policies, rather than duplicating this logic in each layer.
Test Each Layer Appropriately: Apply testing strategies suitable for each layer, such as unit tests for the domain layer, service-layer tests for orchestration logic, and integration tests for persistence adapters.
Document and Enforce Interactions: Maintain up-to-date dependency diagrams and use automated architecture tests to prevent developers from creating "shortcut" dependencies that violate the layering rules.
Key Deliverables
An Architecture Decision Record (ADR) that captures the responsibilities of each layer, the allowed dependencies between them, and the policy for any exceptions.
A formal dependency diagram stored with the project documentation.
Automated architectural checks (e.g., using ArchUnit, dep-cruise, or custom scripts) to prevent rule violations from being merged.
5-Layer: UI → Controller → Service → Domain → Persistence
Real-World Examples
Enterprise ERP Systems: SAP and Oracle ERP use layered architecture to separate user interfaces from business logic and database operations, enabling different frontend applications to share the same business rules.
Banking Applications: Financial institutions employ layered architecture to maintain strict separation between customer-facing interfaces, transaction processing, and secure data storage for regulatory compliance.
E-commerce Platforms: Traditional e-commerce sites use layered architecture to separate product catalogs, shopping cart logic, order processing, and payment handling into distinct layers.
Risks & Mitigations
Excessive Rigidity and Latency:
Mitigation: For features that span multiple layers, strict adherence can lead to excessive "pass-through" code and increased latency. In such cases, consider using a Façade pattern to provide a more direct interface where appropriate.
"Leaky" Layers:
Mitigation: Developers may be tempted to bypass architectural rules for expediency, which degrades the architecture. Treat all architectural violations as build-breaking failures or critical issues in code review.
Concrete Components
These vocabulary items name the concrete tools and abstractions
that show up when the paradigm is implemented. They are not
required dependencies and they are not part of the skill's
tools: frontmatter (which is reserved for Claude Code tool
restrictions). Use this list to disambiguate during architecture
discussions.
dependency-validator: fails the build when a layer imports above its allowed depth
layer-enforcer: static-analysis gate that checks namespaces match layer rules
architecture-compliance-checker: diffs the implemented layer graph against the documented one
Exit Criteria
[ ] An ADR captures the chosen layer stack (3-layer, 4-layer, or 5-layer), responsibilities
per layer, allowed dependency direction, and the policy for cross-layer exceptions.
[ ] A formal dependency diagram is committed to project documentation and matches the ADR's
stated layer boundaries.
[ ] Automated architectural checks (ArchUnit, dep-cruise, or equivalent) are wired into CI
and fail the build on any upward dependency.
[ ] Cross-cutting concerns (logging, auth, validation) are implemented once as middleware or
policy and are not duplicated across layer implementations.
How to use it
Copy the folder
Take athola/architecture-paradigm-layered from the repository into ~/.claude/skills for personal
use, or into .claude/skills inside a project.
Check the name does not clash
The agent identifies a skill by the name field in its header. Two skills with the
same name cannot sit side by side — one of them will be ignored.